|
|
|
|
Auto Failover
auto failover for iSCSI systems
|
|
Backup/restore
Information regarding backup and restore procedures.
|
|
Bonding/teaming
Information regarding bonding/teaming/MPIO.
|
|
Console tools
Information regarding tools and settings available via the console.
|
|
Data replication
Information regarding data replication.
|
|
Directory services
Articles devoted to directory services, such as LDAP and ADS.
|
|
Fibre Channel
A repository of FC knowledge.
|
|
How to Video's
This will contain video as to how to configure the system
|
|
iSCSI
Information on all things iSCSI.
|
|
NAS
Information on NAS protocols and how the function in Open-E software.
|
|
NFS
How-To's and information related to NFS use and configuration in the GUI
|
|
Performance
Tuning options for improving/maximizing performance with Open-E
|
|
RAID
Information regarding both software and hardware RAID.
|
|
Snapshots
All you have ever wanted to know about snapshots.
|
|
SNMP
All question related to SNMP
|
|
Virtualization
A repository of information regarding virtualization solutions and Open-E.
|
|
Volume replication
Information regarding volume replication.
|
|
Miscellaneous
Any articles which do not fit other subcategories.
|
|
UPS
Backup Power supply setup and configuration information
|
|
Updates
How to update the DOM with new releases and small updates
|
|
Boot Media
|
|
Where can I find usefull informations about DSS V7 setup and features ?
There are several places where you can search for the information you are looking for. Below you can find some of them Webcast and Videos http://www.open-e.com/service-and-support/library/webcasts-and-videos/ ...
|
|
05 Apr, 2013
Views: 2035
|
|
|
DSS loosing Activated Status after reboot on XEN
I've installed DSS no my XEN server. After reboot it's loosing activated status. What should I do? Solution: Find unique dss.cfg* file of your VM with DSS and add following line to the file: uuid = '54443858-4E54-2500-904C-0025904C93D8' ** *where dss is name of your VM **Where ...
|
|
26 Mar, 2013
Views: 1291
|
|
|
Can I remove logical volume without restart of Open-E?
Can I remove logical volume without restart of Open-E? Solution: Yes you can. You just have to perform few actions via the WebGUI: - make sure that volume is not assigned to any target or shares...
|
|
26 Mar, 2013
Views: 3365
|
|
|
DSS V7/DSS V6 TCP zero copy error message in dmesg
It may happen that the following warning will appear in the DSS V6 event viewer and in the dmesg logs: CONFIG_TCP_ZERO_COPY_TRANSFER_COMPLETION_NOTIFICATION not enabled in your kernel. ISCSI-SCST will be working with not the best performance. Refer README file for details. But it doesn't...
|
|
26 Mar, 2013
Views: 1246
|
|
|
DSS V7 Failover function description
Function: Failover Manager The failover manager provides an overview of the cluster configuration and allows starting and stopping the cluster. start Start button is shown when the failover hasn't been started. Use it to start the failover process. When the configuration verification mechanism is...
|
|
26 Mar, 2013
Views: 1486
|
|
|
What WWN stands for?
WWN - Worldwide name, this is a unique identifier in a Fibre Channel storage network. Each WWN has a fixed 64-bit name assigned by the manufacturer and registered with the IEEE to ensure that it is globally unique. It may only include characters from A to F, a to f, digits from 0 to 9 and the :...
|
|
20 Mar, 2013
Views: 1265
|
|
|
How to setup S/W RAID e-mail notification
Function: S/W RAID e-mail notification It is possible to send notification via e-mail about events on software RAID arrays (e.g. rebuild started, rebuild finished, RAID degraded). In order to do so, please check the Send array events box. NOTE: In order to be able to send array events via e-mail...
|
|
19 Mar, 2013
Views: 1059
|
|
|
Creating Disk Array with DSS V7
If your system has a hardware RAID, please create a RAID array in the RAID controller setup. Please refer to the RAID controller manual. You do not have to install drivers or RAID array monitoring and maintenance software. If your system has motherboard RAID functionality, please do not use it as...
|
|
19 Mar, 2013
Views: 2069
|
|
|
Adding Disk Array
Adding Disk Array - In the menu, please select “CONFIGURATION” -> ”volume manager” and “Unit manager”. - You will find a list of available drives/arrays (units) that can be used. - When creating a new volume group, the system adds...
|
|
19 Mar, 2013
Views: 1315
|
|
|
How to create iSCSI target volume with DSS V7
After creating an iSCSI volume, please choose “CONFIGURATION” -> ” iSCSI target manager” -> ”Targets” and within the “Create new target” function click the “Apply” button to create a new iSCSI target. Next, in the “Targets” diagram click on the name of a target you...
|
|
19 Mar, 2013
Views: 1379
|
|
|
The Knowledge base is managed by
Open-E data storage software company.