Open-E Knowledgebase
iSCSI problems
iSCSI connection errors with Xen and other virtualization environments.
In some instances, using non-standard iSCSI IQN naming can cause connecton problems. For example you may see an error similar to: (From Xen): Normal 0 false false false EN-US X-NONE X-NONE 'Error connecting, target not found, check user name and password.' Even...
rating 13 Nov, 2014 Views: 1281
How to tune Infiniband on DSS
In case you are interested on tunning options for your Infiniband interfaces you can perform following changes from the console:  - change infiniband mode from datagram to connected  - in DSS can be done as CTRL+ALT+W -> Infiniband tuning) - after changing to connected mode...
rating 15 Mar, 2013 Views: 1317
iSCSI connection problems in ESXi 5.0
Disable Interrupt Remapping in ESXi 5.0 If you're running ESXi 5.0 and DSS V6 build 5845 (version: 6.0up90.8101.5845) and you are experiencing issues with iSCSI connections and drop outs for short periods of time and the following alert appears in the vmkernel/messages log files: ALERT: APIC:...
rating 15 Mar, 2013 Views: 4956
After re-arranging the LUNs to separate targets I can't have my datastore mounted correctly by VMware.
After re-arranging the LUNs to separate targets I can't have my datastore mounted correctly by VMware. Sulution: The problem is caused by UID's. When UID of discovered target doesn't match the actual UID VMware considers it as a shapshot. To solve this issue force mount the target by it's vmfs...
rating 11 Jan, 2013 Views: 1210
Multiple iSCSI connections
Symptom: My iSCSI targets report that I am having corruption Problem: With iSCSI you cannot have multiple connections to the same LUN, iSCSI Target works block based - not file based. Meaning that a changes made by one person is not seen by another person working on the same...
rating 27 Feb, 2012 Views: 9749
Issue with long booting of VMware ESX 5.0 connected to iSCSI targets
 If you experience a really long booting process of your VMware ESX 5.0 servers that are connected to the DSS V6 iSCSI targets, try to remove the VMKernel Port Bindings - see the images below. Please also make sure that in the iSCSI initiator properties you use is set to Static...
rating 21 Oct, 2011 Views: 2215
Expanding iSCSI Volumes in failover configuration
Expanding a iSCSI Volume that is used in failover configuration and volume replication. This can be done in 6 easy steps. 1- Stop the Auto Failover service on the Primary and Secondary 2- Stop and Delete the Volume Replication Tasks on the Primary 3- Disable the Replication feature...
rating 07 Jul, 2011 Views: 2780
How can we improve high latency links using MaxOutstandingR2T iSCSI parameter?
If you are experiencing high latency or decreased transfer rates between iSCSI initiators and targets, try to tune with the MaxOutstandingR2T iSCSI parameter. A detailed explanations about how this parameter works can be found under the following link: ...
rating 18 Apr, 2011 Views: 5268
Open-E storage cannot pass Windows cluster Validation test
Symptom: Open-E storage cannot pass Windows cluster Validation test Problem: Errors when validating that storage supports the SCSI-3 Persistent Reservation commands The following errors appear on initiator site (Windows 2008 R2): Validating Cluster Disk 0 for Persistent Reservation...
rating 06 Apr, 2011 Views: 2711
After update to DSS V6 build 4786 or to build 5087 with a Xen Citrix or Vmware ESXi Servers the iSCSI Targets are not recognized by IET standard
Problem:  After update to DSS V6 build 4786 to build 5087with a Xen Citrix Server or VMware ESXi Servers the iSCSI Targets are not recognized by IET standard. Solution:  1. Power off the guest and/or Virtual Machines (Virtual Machine located on Open-E DSS IET iSCSI Target) and...
rating 14 Jan, 2011 Views: 2200

← Prev Next
1 2 3

The Knowledge base is managed by Open-E data storage software company.