The FC initiator cannot see FC target on DSS V6, V7

Symptom:

The FC HBA initiator cannot see any FC targets configured on DSS V6 or DSS V7.

Problem:

This seems to be a related to driver mode of FC HBA.

Solution:

Please go to Console Tools (CTRL+ALT+T) -> Modify driver options -> qla2xxx -> qlini_mode and try following possible values:

 "exclusive" - initiator mode will be enabled on load, disabled on enabling target mode and then on disabling target mode enabled back;

 "disabled" - initiator mode will n ever be enabled;

 "enabled" (default) - initiator mode will always stay enabled.