Configuring LSI RAID Controller alerts sent to DSS V7

Alerts sent to DSS V7 from the LSI MegaRAID Controller can be enabled, or disabled in the following categories: Information, Critical, and Fatal.
To do this, you may disable them, by category, or individually, from the 'System Log' on the controller. To do this, you need use MegaRAID Storage Manager and go to Tools -> Configure Alerts -> Alert settings and enable/disable "System log" for desired category. Please refer to attached screenshot.

If you disable sending the event(or category of events) to the 'System log', The DSS V7 will not recieve the message, will not send it to the event viewer, and will not send an email alert.